Iran Radiator Gas Burners

Key Features

  • Offers 29 models for varied requirements
  • Thermal capacity spans from 17,000 to 6,000,000 Kcal/h
  • Pipe dimensions range from 92×370 to 165×380
  • Modes vary from single-stage to three-step operations
  • Some models feature advanced control boxes
  • Designed for optimal energy efficiency
  • Suitable for both residential and commercial spaces
  • Engineered for consistent and reliable performance
  • Ensures safety with industry-standard protocols
  • Streamlined installation and user-friendly operation

 

Iran Radiator Gas Burners: An Introduction

In the realm of thermal solutions, Iran Radiator stands out as a pivotal manufacturer of gas burners. Drawing on years of expertise and state-of-the-art technology, these gas burners promise efficiency, reliability, and safety. Here’s a deeper look into the features and specifications:

 

Diverse Selection for Varied Needs

Iran Radiator boasts a selection of 29 unique gas burners, ensuring that users can find a burner tailored to their specific requirements.

 

Thermal Capacity

The range is extensive, spanning from a modest 17,000 Kcal/h to a robust 6,000,000 Kcal/h, catering to both domestic and industrial applications.

 

Pipe Dimensions

Models are available with pipe dimensions that range from 92×370 to 165×380, offering flexibility based on installation needs.

 

Modes of Operation

Depending on the model, users can choose from single-stage operations for simpler needs or go up to three-step operations for more intricate processes. Some even come with advanced control boxes for an enhanced control experience.

 

Optimal Energy Efficiency

The design of these burners focuses on conserving energy, thereby contributing to more sustainable practices and potentially reducing operational costs.

 

Versatile Applications

Perfectly suited for both residential and commercial setups, these burners can handle a variety of thermal tasks.

 

Reliability

Each burner is engineered for consistent performance, ensuring that users get a dependable heat source.

 

Safety Protocols

Drawing from the text, the safety of Iran Radiator’s gas burners is paramount. They come equipped with features such as automatic shutdown during malfunctions, ensuring users’ peace of mind.

 

Ease of Installation and Use

Streamlined designs make these burners straightforward to install. Moreover, their user-friendly operations make them a breeze to use, even for those unfamiliar with gas burner systems.

 

One-year Warranty

Iran Radiator Burners come with a one-year warranty. This ensures customer confidence in the product’s quality and the company’s commitment to addressing any potential issues.

 

How Gas Burners work

The most commonly used and simplest burners of Iran Radiator are the gas burners.

Gas burners have a straightforward operation. The way they work is that natural gas passes through a filter to reach the nozzle tip. Upon mixing with air and with the activation of the ignition transformer, it becomes a flame.

The safety of Iran Radiator’s gas burners is very high. They automatically shut off if a malfunction occurs at any stage.

 

Main Components of Iran Radiator’s Gas Burner

Electric Valve:

The electric or magnetic valve is placed in the gas pathway to create an optimal flame. Its role is to gradually and gently open the gas path until the flame stabilizes.

 

Gas Pressure Control Switch:

If the incoming gas pressure is lower than normal, the gas pressure control switch closes the electric valve, preventing gas inflow.

 

Air Pressure Control Switch:

Just as incoming gas to the burner is controlled, the incoming air pressure to the burner is monitored by the air pressure control switch. The air, supplied by a fan to the burner, must be sufficient for combustion. When the required air is supplied by the fan, a confirmation command is issued from the air pressure control switch to the burner relay. Otherwise, the burner turns off.

 

Gas Burner Control Relay:

The most crucial part of the gas burner is the control relay since all commands are sent to the relay. If all stages of the process are correct, the burner is turned on; otherwise, it turns off.

 

Ion:

For flame control in Iran Radiator’s gas burners, an ion system is utilized. However, in diesel or dual-fuel burners, a photocell or “eye” system is used.

 

Spark Electrodes or Ignition Transformer:

After all input processes are verified to be correct, the burner relay sends a combustion command to the spark electrodes.

ModelThermal capacityABCDE∅FGHJ∅KL∅M∅NR″
GMG - 85 85,000 406 285 372 100 102 115 252 166 118 200 162-202 150-170 120 1/2
GMG - 110 100,000 406 285 372 100 102 115 252 166 118 200 162-202 150-170 120 1
GMG - 220 190,000 406 355 440 100 102 115 252 166 180 200 162-202 150-170 120 1
ModelPipe dimensionsABCDD NElectrical control boxMode of operationThermal Capacity (Kcal/h)
F 55 - 350 95 80 264 1/2" - Single Stage 17000-43000
F 88 - 360 95 88 264 1/2" - Single Stage 25000-86000
RAN 25 Ø 92x300 417 97 88 453 1/2" - Single Stage 37000-102000
JGN 80/0 Ø 122x370 552 140 110 485 1" - Single Stage 42000-155000
JGN 80/1 Ø 122x370 552 140 110 485 1" - Single Stage 52000-172000
JGN 80/2 Ø 122x370 552 140 120 485 1" - Single Stage 52000-225000
PGN 0 Ø 165x380 700 170 153 585 1" - Single Stage 110000-325000
PGN 0 A Ø 165x380 700 170 153 625 11/2" - Single Stage 130000-390000
PGN 0 SP Ø 165x380 700 170 153 695 11/2" - Single Stage 130000-390000
PGN 1 A Ø 165x380 810 200 165 710 11/2" - Single Stage 212000-500000
PGN 1 B Ø 165x380 810 200 165 710 11/2" - Single Stage 212000-600000
PGN 1 C Ø 165x380 810 200 165 780 11/2" Connected Two Steps 212000-800000
PGN 1 - 810 200 165 675 11/2" single Two Steps 212000-800000
PGN 1 SP - 810 200 165 675 11/2" single Two Steps 297000-1070000
PGN 2 A - 960 220 194 780 2" single Two Steps 424000-1500000
PGN 2 - 960 220 194 810 2" single Two Steps 424000-1800000
PGN 2 SP - 960 220 219 810 2" single Two Steps 500000-2260000
IG 1700 - 1306 246 219 857 2" connected Two Steps 425000-1500000
IG 2100 - 1306 246 254 857 2" connected Two Steps 620000-1900000
IG 2800 - 1306 246 254 857 2" connected Two Steps 660000-2400,000
IG 3400 - 1700 300 340 1576 DN 65 Single Three Steps 800000-3000000
IG 4400 - 1550 300 340 1835 DN 80 single Modulation 660000-4000,000
IG 4400M - 1700 300 340 1576 DN 80 Single Three Steps 1000000-4000000
IG 5800 - 1800 300 340 1835 DN 100 single Modulation 835000-5000000